Innovations
Preventing problems caused by steam condensate
Since steam is the vapor phase of water, condensation occurs under various conditions, whether intended or unintended, resulting in condensate accumulating somewhere in the system. Condensate moves toward the low points of the system, where it can remain and cause damage to valves and piping if it is not removed.
Corrosion: Accumulated condensate can collect in pipes, valves, and equipment. If left standing, the water can cause corrosion, even in materials that are resistant to corrosion. In addition, if carbon dioxide is present in the piping, it can combine with condensate water to form carbonic acid, worsening corrosion problems.
Reverse Flow: Excessive condensate in the wrong location can cause condensate or steam to flow in the opposite direction to that intended. Condensate may flow back to an area where it heats up again and rapidly turns into steam. According to Bregman, valves that have already suffered corrosion due to condensate accumulation are particularly susceptible to reverse flow. This can lead to inaccurate flow meter readings and potentially dangerous pressure spikes.
Steam Condensate Flashing: In areas where large amounts of condensate accumulate, flowing steam may push the condensate into a region where it rapidly vaporizes. This process generates tremendous forces that can destroy pipes, valves, or heat exchangers.
The first occurs in liquid-only systems, where pressure spikes may be caused by valves closing or pumps shutting down suddenly.
The second occurs in steam systems where condensate accumulates and subsequently flashes into steam. As the water changes into vapor, its volume can increase by approximately 500–600 times. This expansion can cause significant pressure changes within the system.
The third and most dangerous type of water hammer also occurs in steam systems and is commonly known as condensate-induced water hammer.
This happens when high-velocity steam flowing through a pipe pushes accumulated condensate forward. The process is similar to wind pushing water across a pond or lake and creating waves. When the steam generates a wave front in the pooled condensate, the rapid transition from liquid to vapor can have dramatic and catastrophic consequences. The steam can propel a large mass of water into a pipe elbow or another restriction at velocities reaching hundreds of feet per second.
One of the most well-known steam explosions occurred in New York City in 2007, when an underground steam line ruptured beneath a street, creating a hole in the pavement large enough to swallow a tow truck.
How can such destructive incidents be prevented?
Steam traps are devices that remove condensate without allowing steam to escape. They should be installed at strategic points throughout the system to prevent condensate accumulation while retaining steam within the system.
Proper thermal insulation is also important in reducing the risk of condensate flashing.
All pipes and valves in the system must be appropriately sized for the required operating conditions.
The type and quality of valves used in condensate systems should also be carefully considered, particularly check valves. Check valves can help manage condensate, but standard off-the-shelf models may not always perform adequately in these applications. Special modifications may be required, such as springs designed for low cracking pressure. A soft seat material may also be advisable to reduce erosion between the closing mechanism and the valve seat.
In addition to preventing damage caused by condensate, effective condensate management allows water to be collected and recycled, reducing the system’s overall water consumption and improving resource efficiency.
Corrosion: Accumulated condensate can collect in pipes, valves, and equipment. If left standing, the water can cause corrosion, even in materials that are resistant to corrosion. In addition, if carbon dioxide is present in the piping, it can combine with condensate water to form carbonic acid, worsening corrosion problems.
Reverse Flow: Excessive condensate in the wrong location can cause condensate or steam to flow in the opposite direction to that intended. Condensate may flow back to an area where it heats up again and rapidly turns into steam. According to Bregman, valves that have already suffered corrosion due to condensate accumulation are particularly susceptible to reverse flow. This can lead to inaccurate flow meter readings and potentially dangerous pressure spikes.
Steam Condensate Flashing: In areas where large amounts of condensate accumulate, flowing steam may push the condensate into a region where it rapidly vaporizes. This process generates tremendous forces that can destroy pipes, valves, or heat exchangers.
PRESSURE SPIKES IN PIPING SYSTEMS
According to Bregman, three different types of pressure-spike scenarios can occur in piping systems.The first occurs in liquid-only systems, where pressure spikes may be caused by valves closing or pumps shutting down suddenly.
The second occurs in steam systems where condensate accumulates and subsequently flashes into steam. As the water changes into vapor, its volume can increase by approximately 500–600 times. This expansion can cause significant pressure changes within the system.
The third and most dangerous type of water hammer also occurs in steam systems and is commonly known as condensate-induced water hammer.
This happens when high-velocity steam flowing through a pipe pushes accumulated condensate forward. The process is similar to wind pushing water across a pond or lake and creating waves. When the steam generates a wave front in the pooled condensate, the rapid transition from liquid to vapor can have dramatic and catastrophic consequences. The steam can propel a large mass of water into a pipe elbow or another restriction at velocities reaching hundreds of feet per second.
One of the most well-known steam explosions occurred in New York City in 2007, when an underground steam line ruptured beneath a street, creating a hole in the pavement large enough to swallow a tow truck.
How can such destructive incidents be prevented?
MANAGING CONDENSATE TO PREVENT DAMAGE
Properly sizing all pipes and valves in the system is essential. According to Bregman, incorrectly sized pipes can be a major cause of condensate accumulation in steam systems. The positioning of condensate return lines in relation to other process equipment is also extremely important. System designers should identify low points where condensate is likely to collect.Steam traps are devices that remove condensate without allowing steam to escape. They should be installed at strategic points throughout the system to prevent condensate accumulation while retaining steam within the system.
Proper thermal insulation is also important in reducing the risk of condensate flashing.
All pipes and valves in the system must be appropriately sized for the required operating conditions.
The type and quality of valves used in condensate systems should also be carefully considered, particularly check valves. Check valves can help manage condensate, but standard off-the-shelf models may not always perform adequately in these applications. Special modifications may be required, such as springs designed for low cracking pressure. A soft seat material may also be advisable to reduce erosion between the closing mechanism and the valve seat.
In addition to preventing damage caused by condensate, effective condensate management allows water to be collected and recycled, reducing the system’s overall water consumption and improving resource efficiency.
Partners